Sonatest SiteScan 250S Flaw Detector

-50%

Original price was: $3.000.Current price is: $1.500.

  • Manufacturer: Sonatest
  • Model: SiteScan 250S
  • Included: Sonatest Sitescan 250S Ultrasonic Flaw Detector (BC#-L/T*), AC Adapter/Charger, User Manual on CDROM, Carrying Case (G)
Compare
SKU: SS250SFD Category: Tag: Product Brand:
Brand:

    Description

    Sonatest SiteScan 250S Flaw Detector includes all the software features of the 150S combined with a narrow band amplifier and TCG for more demanding ultrasonic applications. The square wave ActiveEdgeTM pulser automatically optimizes for each filter band selected, ensuring maximum performance.

    Sonatest SiteScan 250S Flaw Detector defects are highlighted in a different color to the natural reflectors, enabling quicker and more reliable defect detection.

    Sonatest SiteScan 250S Flaw Detector offer a range of measurement options for signal height or distance using either flank or peak triggering Curve Surface Correction. Sonatest SiteScan 250S Flaw Detector will calculate the surface distance and depth of defect, Sonatest SiteScan 250S Flaw Detector taking into account the internal or external radius Flaw Sizing.

     

    Sonatest SiteScan 250S Flaw Detector Features:

    • Sunlight viewable, color trans-reflective TFD display
    • Easy-to-use, user friendly operating system
    • DAC, AWS, API and DGS (AVG) included at no extra cost!
    • Digital flaw location (thickness and angle beam trig.)
    • Curve correction
    • Full screen A-Scan display
    • Waterproof – IP67 case
    • Shockproof case
    • 15 hour battery life!
    • BNC or Lemo Connectors – your choice
    • Wide band amplifier
    • Affordable price
    • Thickness Data Logger (8,000 readings)
    • Auto-Cal for fast set-up
    • 2 gates
    • Depth/E-E/Trig measurement
    • Auto-Cal
    • DAC/AWS/AVG
    • 8000 thickness readings storage capacity

     

    Sonatest SiteScan 250S Flaw Detector Included:

    • Sonatest Sitescan 250S Ultrasonic Flaw Detector (BC#-L/T*)
    • AC Adapter/Charger
    • User Manual on CDROM
    • Carrying Case (G)

     

    You may also be interested in Leica ScanStation P40

     

    Sonatest SiteScan 250S Flaw Detector Specifications:

    Test Range 0-5mm (0.2in) up to 0-10000 (400in) at steel velocity. Variable in sequence, 10mm or 1mm
    Velocity 1000 – 9999 m/s
    Probe Zero 0 – 999.999 us
    Delay 0 – 10000m at steel velocity in 0.05 steps (0 – 400 in 0.002 in steps)
    Gain 0 – 110dB in 0.5, 1, 2, 6, 10, 14, 20 dB steps
    Test Modes Pulse echo and transmit-receive
    Gates Two fully independent gates for echo monitoring and thickness measurement. Start and width adjustable over full range of unit, amplitude variable from 0 to 100% FSH. Bar presentation. Positive or negative triggering for each gate with audible and visual alarms.
    Measurement Modes
    Depth Depth and amplitude of signal in gate
    Echo – Echo Echo – Echo distance, automatic gate 2 position
    Gate to Gate Echo – Echo distance, manual gate 2 position
    Trig Trigonometric display of beam path, depth and surface distance Calculation of skip depth and curve surface compensation, X-offset for transducer
    T-Min Holds minimum thickness in depth mode
    Pulser Voltage -200 volt peak amplitude, rise/fall time <10ns into 50 ohm
    Pulser Width Fixed 100ns 30 – 250 ns linked to filter band
    Pulser Repetition Frequency Selectable 5 – 1000Hz.
    Display Colour transflective TFT Display area 111.4 x 83.5mm (4.39 x 3.29 in) A-scan area 315 x 200 max Variable brightness Sunlight viewable
    8 Selectable colour schemes for A-scan & menu
    Screen Update Rate 50 or 60Hz
    Rectification Full Wave, positive, negative, RF
    Frequency Bands Broadband 1 – 10 Mhz (-6dB)
    Vertical Linearity 1% full screen height
    Amplifier Linearity +- 0.1 dB
    Horizontal Linearity 0.33% full screen width
    Reject 50% Suppressive LED warning light when activated
    Waveform Smoothing Produces a smooth signal envelope
    Units mm, inches or time
    AGC Automatic Gain Control sets selected echo to a user defined level (10-90%)
    DAC Up to 10 points may be entered and used to digitally draw a DAC curve Reference -2, -6, -10, -12, -14 dB curves can be selected for JIS, ASME and EN1714 codes
    AWS Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code
    API Automatic defect sizing in accordance with API 5UE
    AVG/DGS Automatic defect sizing using probe data
    TCG Time corrected Gain 40dB dynamic range, 30dB per microsecond, up to 10 points for curve definition.
    A-scan Memory 800 waveforms
    Panel Memory 100 stores for calibration setting
    Thickness Logging 8000 readings stored in Block/Location/Number coding or alpha-numeric pre-programmed work sheets Transferable to Excel using optional SDMS
    Auto-Cal Automatic calibration with two echoes
    Reference Waveform Recalled waveform can be shown in a different colour to live waveform for direct comparison
    Display Freeze Holds current waveform on screen
    Peak Memory For echo-dynamic pattern capture
    Front USB For connection to PC, keyboard and printer
    Outputs Serial Interface, composite video (PAL & NTSC), analogue output for amplitude and distance updated at PRF rate Transmitter sync output
    Battery Lithium Ion 14.4V 5.0 ampere hours Up to 16 hours, indication of battery charge. Recharge time 4 hours. Mains pack option
    Charger 100 – 240 VAC, 50-60Hz
    Environmental Meets IP67
    Temperature Range Operating -10o C to 55o C (14o F – 131o F) Storage -40o C to 75o C (-40o F to 167o F)
    Size 256 x 145 x 145mm (10 x 5.7 x 5.7 in.)
    Weight 2.5Kg (5.5 lbs) with battery

    Additional information

    Weight 10 kg
    Dimensions 60 × 60 × 50 cm
    color

    Gray

    Reviews

    There are no reviews yet.

    Be the first to review “Sonatest SiteScan 250S Flaw Detector”

    Your email address will not be published. Required fields are marked *